• has good insulating properties; • have good flexibility; • Minimum shrink temperature: 110 ℃;
Application: This product is widely used in low voltage switch cabinet bus insulation protection, effectively prevent personal injury or death caused by the charged row naked; to avoid a small animal and the conductor ride then cause a short circuit, discharge failure occurs, to prevent corrosion, contamination, flashover occurs, increase insulation margin, effectively shortening the distance between the stage, the pole distance, create favorable conditions for switchgear compact design.

">   • has good insulating properties; • have good flexibility; • Minimum shrink temperature: 110 ℃;
Application: This product is widely used in low voltage switch cabinet bus insulation protection, effectively prevent personal injury or death caused by the charged row naked; to avoid a small animal and the conductor ride then cause a short circuit, discharge failure occurs, to prevent corrosion, contamination, flashover occurs, increase insulation margin, effectively shortening the distance between the stage, the pole distance, create favorable conditions for switchgear compact design.

" />   • has good insulating properties; • have good flexibility; • Minimum shrink temperature: 110 ℃;
Application: This product is widely used in low voltage switch cabinet bus insulation protection, effectively prevent personal injury or death caused by the charged row naked; to avoid a small animal and the conductor ride then cause a short circuit, discharge failure occurs, to prevent corrosion, contamination, flashover occurs, increase insulation margin, effectively shortening the distance between the stage, the pole distance, create favorable conditions for switchgear compact design.

">

CYG-BT(35H) High Voltage Flame-retardant Wall Heat Shrinkable Busbar Sleeving

Category: Heat Shrink Dual Wall Sleeving

Product manual

Material: radiation cross-linked modified polyolefin material
Shrink ratio: 2.5: 1
Features:
  • Environmentally friendly, low smoke, the product complies "RoHS" environmental standards;
  • has good insulating properties; • have good flexibility; • Minimum shrink temperature: 110 ℃;
Application: This product is widely used in low voltage switch cabinet bus insulation protection, effectively prevent personal injury or death caused by the charged row naked; to avoid a small animal and the conductor ride then cause a short circuit, discharge failure occurs, to prevent corrosion, contamination, flashover occurs, increase insulation margin, effectively shortening the distance between the stage, the pole distance, create favorable conditions for switchgear compact design.

ItemTest methodIndicatorValues
Tensile strengthASTM D2671≥10MPa14.3MPa
Elongation at breakASTM D2671≥450%485%
Tensile Strength After AgingASTM D2671/136°C/168h≥10MPa12.5MPa
After aging the tensile elongation at breakASTM D2671/136°C/168h≥400%436%
Thermal Shock200°C±3°C/4hWithout dripping, flowing or crackQualified
Low temperature flexibilityASTM D2671/-40°C/4hNo crackingNo cracking
Breakdown strengthASTM D2671≥19kV/mm≥23.5kV/mm
Volume resistivityASTM D876≥1.0x10¹²Ω· cm≥4.5x1014Ω· cm
Water absorptionASTM D570A≤0.5%0.31%